PDF Print E-mail

Flat collector ES1V/2,65

ES1V265S__ES1V265BFlat collector about the area 2.65 m 2 for the vertical assembly. The structure of the collector is leaning against the double harp absorber.

Collector of series E S 1 V/ 2,65 are offered in two colour versions:

ES1V/2,65S – colour of natural aluminium
ES1V/2,65B – collector anodized in dark- brown colour


Advantages of using the double harp absorber:

  • the intake of the factor and the take-off are on one level. Such a solution is reducing the number connector pipe additive only to two what the quantity of connecting elements is making smaller as well as he is shortening the time of the assembly..
  • linking Ensol collector in the battery doesn’t require balance beam plumbing because collector are being linked in series and because of that the flow in each of them is identical.
  • in the case if some of collectors in the battery was disabled (e.g. obstructed) it would be while starting the installation it at once visible through the lack of the flow of the factor in the entire installation (series connection)..
  • the flow in the collective pipeline is equal of the nominal flow for one connector what is important solar installations because is reducing capital costs (smaller diameters of pipelines, smaller circulation pumps, and consequently also less of solar liquid)..



    • technical parameters:

      Symbol Unit Wartość
      breadth A mm 1120
      height B mm 2356
      depth C mm 85
      weight of collector m kg 49
      surface S m2 2,65
      optical efficiency ηo % 79,8
      coefficient a1 W/(m2K) 3,688
      coefficient a2 W/(m2K) 0,019
      service line: pipe Cu ø mm 22
      enclosure aluminium profile
      cover Szkło solarne pryzmatyczne gr. 4mm
      Absorber:
      kind of absorber metal sheet Cu thickness 0,2 mm
      High-selective cover Blue Tec – eta plus
      technology of execution ultrasonic welding
      absorption coefficient α % 95
      emission coefficient ε % 5
      breadth a mm 1066
      height b mm 2303
      Absorber surface Sb m2 2,45
      netto surface Sn m2 2,46
      contents of liquid V dm3 2,2
      balance temperature Tr °C 208
      guaranteed minimal thermal output kWh/m2∙rok 525
      flow:
      recommend
      permissible

      l/h
      l/h

      ok. 75
      60-250
      insulation rock wool
      conduction coefficient λ w/mK 0,035
      thickness of insulation layer
      lower d mm 40
      lateral d1 mm 10
      Research Report TÜV Köln 21212847
      Solar Keymark 011-7S1302 F


solar glass gr. 4mm
 